EGSE Time 04/20/24 08:12:03.429 UTC APID1840 Time 04/20/24 07:30:37.237 UTC IRIS IAU FSW COMMAND SOLAR ARRAY & BATTERY CHARGE CONTROL MENU Cell Overvolt 1 NOMINAL Cell Overvolt 2 NOMINAL BRE BUILD VER 113 B_HW_BATTERY_VOLTAGE 28.54 V GOOD B_HW_CPU_ACTIVE 0xCAFE Re Qual ALL ACS BUILD VER 3326 B_MM_MCLASI_VOLTAGE 28.60 V GOOD B_HW_BATTERY_CURRENT 0.12 A GOOD DB BUILD VER 2657 B_HW_LOAD_CURRENT 10.49 A GOOD B_HW_SA_CURRENT 10.26 A GOOD GSE DB BUILD VER 2662 B_HW_PAPI_1_CURRENT 1.71 A B_HW_PAPI_4_CURRENT 7.68 A ------------------------------------------------------------------------------------------------------------------ LV SEP STATUS SEP LV SEP SW1 OPEN LV SEP SW2 OPEN LV SEP SW3 OPEN Battery Avg. Temp (C) -0.68 ----------------------------------------------------------------------------------------------------------------- SACI Switch ID HW SW SA Enable SW Commands Battery Charge Control Mode BCC_ENABLED -> FSW Solar Array Switch 1 ON ON ENABLED OFF ON Hardware Software Test Mode Solar Array Switch 2 ON ON ENABLED OFF ON BCC Batt. Voltage Used 28.54 V GOOD Solar Array Switch 3 ON ON ENABLED OFF ON BCC Batt. Current Used 0.25 A GOOD Solar Array Switch 4 ON ON ENABLED OFF ON BCC Voltage Setpoint 28.80 V Change Solar Array Switch 5 ON ON ENABLED OFF ON BCC Volt Hysteresis 0.30 V Change Solar Array Switch 6 ON ON ENABLED OFF ON BCC Voltage Start BCR 33.00 V Change Solar Array Switch 7 ON ON ENABLED OFF ON BCC Voltage End BCR 27.00 V Change Solar Array Switch 8 ON ON ENABLED OFF ON BCC SA Cycles/show [irismds.amn.nasa.gov, b_EPS_SA_BCC.page] cmd 1 Change Solar Array Switch 9 ON ON ENABLED OFF ON BCC SA Mask 4095 / fff Change Solar Array Switch 10 ON ON ENABLED OFF ON Battery State Of Charge 0.998859 RESET Solar Array Switch 11 ON ON ENABLED OFF ON Battery SOC Reset Flag Reset_Done Solar Array Switch 12 ON ON ENABLED OFF ON SOC Reset Time 04/10/24 06:10:04.938 GMT -------------------------------------------------------------------- Time Since SOC Reset 868828.3 sec Battery Charge Removal (BCR) SOC Reset Mode TAPER_CURRENT BCC BATT CHARGE REMOVAL ENABLED DISABLED Taper Current Target -0.60 A BCR CHARGE REMOVAL AMNT 1.500 Ah Battery Capacity Available 29.9657612 Ah Rated 30.0 Ah BCR BATTERY CHARGE REMOVED 0.000 Ah EPS Reassert State ENABLED High Discharge Rate Counter 0 Threshold 15.0 A